New Build Air Tightness Testing – When is a Building Ready?
This is a question we get asked frequently. Pre-testing can be done anytime once the building is wind and water tight, generally before plasterboard is installed, to ensure it’s on the right track.
However, for official certification, the following must be completed before the test can take place:
- Drainage traps – filled with water or sealed (penetrations must be made).
- Service penetrations – incoming or outgoing services installed with permanent sealing completed around all penetrations.
- External doors and internal garage doors – fitted with seals and closed as required.
- External windows – fitted with seals and closed.
- Electrical items – sockets must be fitted to the wall (no items plugged in except as needed for fan operation).
- Light switches – fitted to the wall.
- Ceiling lighting – installed.
- Internal doors – able to be restrained open for the test.
- Heating systems – installed.
- Ventilation systems – installed, including trickle vents if applicable.
- Kitchen units – installed.
- Loft hatches – installed.
Tips and Important Considerations
- Pre-testing is helpful: Conducting a pre-test before plasterboard is installed can identify areas needing attention early, saving time and stress ensuring you build is on track.
- Occupancy: No one can enter or exit the building during the test, so the building should be unoccupied.
- Weather conditions: High wind speeds can invalidate the test. If the weather is unsuitable, a new test date will be arranged.
Have a project coming up or need advice?
Contact us today for a free no-obligation quote.
Call Wendy on 07477 434461
Email: wendy@albaatt.co.uk
What Our Customers Say
We’re proud of the relationships we build with our clients. Here’s what homeowners, builders, and architects have to say about working with Wendy and Alba Air Tightness Testing.
“Absolutely brilliant service from Wendy. She helped us through our preliminary air test, identifying areas for improvement and indeed helping us to rectify some of those. We then used Alba Air Tightness Testing again for our certificate test and Wendy was friendly, helpful and efficient. Can't recommend highly enough!”
Simon & Emma Candy
“Delighted with the quick response from Wendy at Alba air tightness testing, explained everything I need to do in preparation as was first time getting air test done. Also I’d say not expensive in today’s terms of getting things done when building a house. Very helpful all-round. Definitely would and will recommend AATT Ltd to anyone looking for this service.”
Colin Soutar
“Highly recommended. Excellent communications and explanations before the test. Very knowledgeable. Arrived when she said she would. Carried out the testing carefully and efficiently. Excellent follow-up.”
Gill sproul
“Wendy is excellent. Professional, punctual and very knowledgeable, it’s so refreshing to deal with someone who clearly cares not only about their job but also the customer. She made recommendations along the way and sent us the certificate the same day. Thank you so much Wendy. Fiona and Greg.”